Page 122 - 2019 SHOP MANUAL CRF1000/A/D
P. 122

du
             dummyheadmmyhead

      PGM-FI SYSTEM
                      DTC 7 (ECT SENSOR)
                                                                            ECM/PCM



                                                                    5 V

                                   ECT SENSOR
                                                       Lg



                                                      Gr/Bl




                      Probable cause
                       • Open or short circuit in the Light green wire between
                        the ECT sensor and ECM/PCM
                       • Open circuit in the Gray/black wire between the ECT
                        sensor and ECM/PCM
                       • Faulty ECT sensor
                       • Faulty ECM/PCM
                      DTC 7-1 (ECT SENSOR LOW VOLTAGE)
                      1. ECT Sensor System Inspection
                         Check the ECT sensor with the MCS.
                         Is about 0 V indicated?
                         YES  – GO TO STEP 2.
                         NO   – Intermittent failure
                      2. ECT Sensor System Inspection with Connector
                         Disconnected
                         Turn the ignition switch OFF.
                         Disconnect the ECT sensor 2P (Black)  connector
                         (page 4-41).
                         Check the ECT sensor with the MCS.
                         Is about 0 V indicated?
                         YES  – GO TO STEP 3.
                         NO   – Faulty ECT sensor
                      3. ECT Sensor Output Line Short Circuit Inspection
                         Turn the ignition switch OFF.
                         Disconnect the ECM/PCM 33P (Gray) connector         [1]
                         (page 4-39).
                         Check for continuity between the wire harness side
                         2P (Black) connector [1] and ground.
                         Connection: Light green – Ground
                         Is there continuity?                                    Lg
                         YES  – Short circuit in the Light green wire
                         NO   – Replace the ECM/PCM with a known good
                                one (page 4-39) and recheck.













      4-14
   117   118   119   120   121   122   123   124   125   126   127