      PGM-FI SYSTEM
                      DTC 9-2 (IAT SENSOR HIGH VOLTAGE)

                       • Before starting the inspection, check for loose or
                        poor contact on the IAT sensor 2P (Blue), ECM/PCM
                        33P (Black)  and  33P (Gray) connectors, and
                        recheck the DTC.
                      1. IAT Sensor System Inspection
                         Check the IAT sensor with the MCS.
                         Is about 5 V indicated?
                         YES  – GO TO STEP 2.
                         NO   – Intermittent failure
                      2. IAT Sensor System Inspection with Jumper Wire
                         Turn the ignition switch OFF.
                         Disconnect the IAT sensor 2P (Blue) connector            [1]
                         (page 4-41).
                         Connect the wire harness side 2P (Blue) connector
                         [1] terminals with a jumper wire [2].
                         Connection: Brown/red – Gray/black
                         Check the IAT sensor with the MCS.                        Gr/Bl  Br/R
                         Is about 0 V indicated?
                         YES  – Faulty IAT sensor
                         NO   – GO TO STEP 3.

                                                                                           [2]
                      3. IAT Sensor Output Line Open Circuit Inspection
                         Turn the ignition switch OFF.
                         Disconnect the ECM/PCM 33P (Gray) connector         [1]            [2]
                         (page 4-39).
                         Check for continuity between the wire harness side
                         2P (Blue) connector [1] and 33P (Gray) connector
                         [2].
                         TOOL:
                         Test probe            07ZAJ-RDJA110
                         Connection: Brown/red – C31                   Br/R                C31

                         Is there continuity?
                         YES  – GO TO STEP 4.
                         NO   – Open circuit in the Brown/red wire
                      4. IAT Sensor Ground Line Open Circuit Inspection
                         Disconnect the  ECM/PCM 33P (Black)  connector
                         (page 4-39).                                         [1]           [2]
                         Check for continuity between the wire harness side
                         2P (Blue) connector [1] and 33P (Black) connector
                         [2].
                         TOOL:
                         Test probe            07ZAJ-RDJA110

                         Connection: Gray/black – B13
                                                                         Gr/Bl                     B13
                         Is there continuity?
                         YES  – Replace the ECM/PCM with a known good
                                one (page 4-39) and recheck.
                         NO   – Open circuit in the Gray/black wire