Page 97 - 2019 SHOP MANUAL CRF1000/A/D
P. 97

dummyheadmmyhead
             du

                                                                                                     MAINTENANCE
               COOLING SYSTEM

                               Check  the radiator air passages  for clogging  or
                               damage.
                               Straighten bent fins, and remove insects, mud or other
                               obstructions with compressed air or low water pressure.
                               Replace  the  radiator if the air flow is restricted over
                               more than 20% of the radiating surface.
                               Inspect the water hoses for cracks or deterioration, and
                               replace them if necessary.
                               Check the tightness of all water hose band screws
                               (page 8-8).



               SECONDARY AIR SUPPLY SYSTEM

                                • This model is equipped built-in secondary air supply
                                 system. The pulse secondary air supply system is
                                 located on the cylinder head cover [1].
                                • The secondary air supply system introduces filtered
                                 air into the  exhaust gases in the exhaust port [2].
                                 The secondary air is  drawn into the exhaust port
                                 whenever  there  is negative pressure  pulse in the  [4]
                                 exhaust system. This charged secondary air
                                 promotes burning of  the  unburned exhaust gases
                                 and   changes  a   considerable  amount  of                                    [3]
                                 hydrocarbons and carbon monoxide into relatively
                                 harmless carbon dioxide and water.          [1]
                               Remove the air cleaner housing (page 7-11).
                               Check the PAIR hoses for deterioration, damage or
                               loose connections.
                               Also, check that the hoses are not kinked, pinched or
                               cracked.
                               – Air suction hose [3] (between the air cleaner housing  [2]
                                 and PAIR control solenoid valve)
                               – Air supply hose [4]  (between the PAIR control
                                 solenoid valve and cylinder head cover)
                               If the air suction/supply hose show  any  signs  of heat  FRESH AIR
                               damage, inspect the PAIR reed valves (page 7-21).  EXHAUST GUS
                               For secondary air supply  system inspection (page 7-
                               18).




























                                                                                                               3-15
   92   93   94   95   96   97   98   99   100   101   102