Page 149 - 2019 SHOP MANUAL CRF1000/A/D
P. 149
dummyheadmmyhead
du
PGM-FI SYSTEM
MAP SENSOR
REMOVAL/INSTALLATION
Remove the air cleaner housing (page 7-11).
[2] [1]
Disconnect the MAP sensor 3P (Black) connector [1].
Remove the screw [2] and MAP sensor [3] from the
throttle body setting plate.
Disconnect the MAP sensor hose [4].
Installation is in the reverse order of removal.
[3]
[4]
ECT SENSOR
REMOVAL/INSTALLATION
Drain the coolant (page 8-4).
[1] [2]
Disconnect the ECT sensor 2P (Black) connector [1].
Remove the ECT sensor [2] and O-ring [3]. [3]
Installation is in the reverse order of removal.
• Replace the O-ring with a new one (do not apply oil).
TORQUE:12 N·m (1.2 kgf·m, 9 lbf·ft)
Fill the and bleed the cooling system (page 8-4).
IAT SENSOR
REMOVAL/INSTALLATION
Remove the air cleaner housing (page 7-11).
[2] [3]
Remove the screws [1].
Remove the IAT sensor [2] and O-ring [3].
Installation is in the reverse order of removal.
• Replace the O-ring with a new one.
TORQUE:1.1 N·m (0.1 kgf·m, 0.8 lbf·ft)
[1]
4-41