Page 152 - 2019 SHOP MANUAL CRF1000/A/D
P. 152
dummyheadmmyhead
du
PGM-FI SYSTEM
RELAY INSPECTION
Remove the FI relay (page 4-43).
[1]
Connect an ohmmeter to the FI relay [1] terminals.
Connect a 12 V battery to the starter relay connector
terminals as shown.
There should be continuity only when 12 V battery is
connected.
If there is no continuity when the 12 V battery is
connected, replace the starter relay.
Install the removed parts in the reverse order of
removal.
4-44