Page 534 - 2019 SHOP MANUAL CRF1000/A/D
P. 534

du
             dummyheadmmyhead

      LIGHTS/METERS/SWITCHES
                      TXD LINE INSPECTION


                       • Check the following items before  starting the
                        inspection:
                        – Check for loose or poor contact on the
                          combination meter  32P (Gray) connector and
                          ECM/PCM  33P connectors, then recheck the
                          DTC.
                      Turn the ignition switch ON with the engine stop switch
                      " " and check the combination meter.
        If the engine stop  The TXD line is abnormal if the combination meter
      switch is in "  ", the  shows the following:
         MIL will stay on  – MIL,  engine  oil  pressure,  engine  coolant
          even when the  temperature, and torque control indicator stay on
        system is normal.
                      – HISS, torque control OFF, S/D/G indicator do not
                        come on
                      – Current/average fuel mileage displays "– –.–" (when
                        running the engine)
                      – Remaining fuel displays " –.–"
                      – Available driving distance displays " – –"
                      – Shift indicator "–" is blinking
                      – Torque control level and engine coolant temperature
                        gauge displays blinking
                      If the TXD line is abnormal, check the following:
                      1. TXD Line Open circuit inspection
                         Turn the ignition switch OFF.
                         Disconnect the ECM/PCM 33P (Black) connector [1]   [1]
                         (page 4-39).
                         Disconnect the  combination meter 32P  (Gray)
                         connector [2] (page 22-12).
                         Check for continuity between the wire harness side
                         33P (Black) and 32P (Gray) connectors.                                  B16
                         Connection: B16 – Black
                                                                     [2]
                         TOOL:
                         Test probe             07ZAJ-RDJA110                  Bl

                         Is there continuity?
                         YES  – GO TO STEP 2.
                         NO   – Open circuit in the Black wire
                      2. TXD Line Short circuit inspection
                         Check for continuity between the wire harness side
                         32P (Gray) connector [1] and ground.       [1]
                         Connection: Black – Ground
                         Is there continuity?
                         YES  – Short circuit in the Black wire                Bl
                         NO   – GO TO STEP 3.


















      22-14