      LIGHTS/METERS/SWITCHES
                      INSPECTION
                      Remove  the open air temperature sensor 2P  (Black)
                      connector (page 22-17).
                      Measure the resistance at the 2P connector [1] of the
                      sensor side.
                      Standard: 4.9 – 5.1 kΩ (25°C/77°F)            [1]

                      Replace the open air temperature sensor if it is out of
                      specification.







      HIGH COOLANT TEMPERATURE
      INDICATOR/ECT SENSOR

                      SYSTEM INSPECTION
                      If the high coolant temperature indicator does not
                      operate properly, check the following:
                      – Combination meter initial operation (page 22-12)
                      – TXD line (page 22-14)
                      – MIL blinking: If the  MIL  blinks 7  (DTC 7-1,  7-2),
                        check the ECT sensor system (page 4-14).
                      – ECT sensor (page 22-18)
                      If the above items are OK, replace the combination
                      meter (page 22-12).

                      ECT SENSOR UNIT INSPECTION
                      Remove the ECT sensor (page 4-41).
                      Suspend the ECT sensor [1] in a pan of coolant on an
                      electric  heating element and measure the resistance
                      through the sensor as the coolant heats up.
                       • Soak the ECT sensor  in coolant  up to  its threads
                        with at least 40 mm (1.6 in) from the bottom of the
                        pan to the bottom of the sensor.
                       • Keep the temperature constant for 3 minutes before
                        testing. A sudden change of temperature will result
                        in incorrect readings. Do not let the thermometer or
                        ECT sensor touch the pan.
                      Measure  the  resistance between the ECT sensor
                      terminals.                                                 [1]
                      Temperature      40°C (104°F)  100°C (212°F)
                      Resistance       1.0 – 1.3 kΩ  0.14 – 0.18 kΩ
                      Replace the ECT sensor if it is out of specification.