Page 535 - 2019 SHOP MANUAL CRF1000/A/D
P. 535
dummyheadmmyhead
du
LIGHTS/METERS/SWITCHES
3. ECM/PCM inspection
Connect the 32P (Gray) connector.
Replace the ECM/PCM with a known good one
(page 22-12), and recheck.
Is the combination meter display normal?
YES – Faulty original ECM/PCM
NO – Faulty combination meter
COMBINATION METER DIGITAL
CLOCK SET PROCEDURE
1. Turn the ignition switch ON.
[3]
2. Press and hold the SET [1] and DOWN [2] buttons, [2]
then the hour digits start blinking.
• The combination meter enters the clock setting [1]
mode.
3. Press the UP [3] or DOWN button until the desired
hour is displayed.
• Press and hold the UP or DOWN button to advance
the hour fast.
4. Push the SET button [1], then the minute digits start
blinking.
[1]
5. Press the UP [1] or DOWN [2] button until the
desired minute is displayed. [1]
[2]
• Press and hold the UP or DOWN button to advance
the minute fast.
[3]
6. Press the SET button [3], then the digital clock is set.
7. Turn the ignition switch OFF.
22-15